| Pall |
Micron |
FMC |
Average Filter, Ratio |
| KZ |
1 |
K1 |
Bx200 @ 1 Micron |
| KP |
3 |
K3 |
Bx200 @ 3 Micron |
| KN |
6 |
K6 |
Bx200 @ 6 Micron |
| KS |
12 |
K12 |
Bx200 @ 12 Micron |
| KT |
25 |
K25 |
Bx200 @ 25 Micron |
|
| Test Containment |
|
AC Fine Test Dust ACFTD |
| Test Oil |
|
MIL H-5606 |
| Terminal Pressure |
|
60 PSID (4.14 bar) |
| |
|
|
| |
|
|
| Element Collapse Press |
|
ANSI B93.25/ISO 2941 |
|
100 PSID ( 6.9 bar ) Minimum |
| Dirt Holding Capacity |
|
ANSI B93.31/ISO 4572 |
|
Varies with media, liquid, flow & differential pressure |
| Flow Fatigue Resistance |
|
ANSI B93.24/ISO 3724 |
|
Element media supported up & down stream |
| Fluid Compatibility |
|
ANSI B93.23/ISO 2943 |
|
Compatible with Petroleum Oils 250 F (121 C) |
| |
|
|
|
Water based fluids, Water Glycol 200 F ( 93 C) |
| |
|
|
|
Phosphate Esters require Viton A "O" Rings |
| Element Integrity |
|
ANSI B93.22 |
|
8 IN. Min. Water column Bubble Point (20.3 cm) |
| Operating Temperature |
|
|
|
-20 + 250 F (-29 + 121 C) |