FILTER-MART:    CENTISTOKES TO SAYBOLT  UNIVERSAL SECONDS CONVERSION

viscen.TIF (44215 bytes)

To convert centistokes to Saybolt Universal Seconds, find the centistokes value on the table at the left and then read across to find the equivalent value in Saybolt Universal Seconds.

Example:

A viscosity of 30 centistokes is equivalent to 140 Saybolt Universal Seconds.

 

Notes:

a)   If the viscosity is given in centipoise (cp), it can be readily converted to centistokes (cs) by the formula:

centistokes =   centipoise / specific gravity

b)   Centistokes are often designated by cSt.

c)   Saybolt Universal Seconds are designated by either SUS or SSU.

 

 DO YOUR OWN VISUAL ASSESSMENT WITHIN MINUTES

Can you afford to wait for a lab's analysis report?

Our FIELD TEST KIT does not replace a full lab analysis, but it will reduce the frequency of such tests and the results are immediate!

The FIELD TEST KIT enables you to visually monitor the contaminant level in your oil under a microscope. Contaminants such as silica sand or wear metal particles are easily identified allowing assessment and appropriate action to be taken immediately. The need for filter replacement or rebuilding of suspected worn components can be identified before inconvenient production downtime or major cost.

The PATCH CARD provides a comparison reference file on oil condition from sample to sample, supporting a preventative maintenance program.

 

Visually monitoring oil quality helps to determine:

1)  if the filter is on by-pass

2)  wearing cylinder seals

3)  wearing internal surfaces such as pump vane tips, bushings, bearings, etc.

4)  effectiveness of system filtration

5)  effectiveness of reservoir air breather

 

 